Installation process of aluminium alloy doors and windows with heat-breaking:
A. The installation of doors and windows must be firm, and the number, location and connection method of embedded parts must meet the design requirements. The fasteners used to fix each reinforced section steel shall not be less than three, the spacing shall not be less than 300 mm, and the distance from the end of the section steel shall not be more than 100 mm. The surface of reinforced section steel, fasteners and hardware shall be treated by corrosion-resistant coating except stainless steel.
B. Installation of doors, windows and glasses should be completed by wet working method and hardened, and doors and windows should be installed by reserved opening method; when doors and windows are installed, the ambient temperature should not be lower than 5 degrees Celsius.
Details of door’s frame display:
Product Details | ||||
Aluminium Profiles | Aluminium Alloy | ALU Wall Thickness | Surface Finishing and Color | |
6063-T5 | 1.2mm--2.0mm, Normally 1.4mm for window, 2.0mm for door | Anodized, Sliver & Bronze | ||
Powder Coating, color should be confirm with buyer | ||||
Electrophoresis, Sliver& Champagne | ||||
PVDF | ||||
With thermal break aluminium system design for more energy saving function | ||||
Glass | Type | Thickness | Color | |
Float glass | Single: 4mm -12mm, Double Glazing (With 6A/9A/12A/27A space) | clear/super clear/ tinted blue/green/coffee brown/gray | ||
Insulated double glass | ||||
Insulated triple glass |